Export iten: EndNote BibTex

Please use this identifier to cite or link to this item: https://tede.unioeste.br/handle/tede/5243
Full metadata record
DC FieldValueLanguage
dc.creatorFicanha, Daniele Cristina-
dc.creator.Latteshttp://lattes.cnpq.br/5848126108132225por
dc.contributor.advisor1Christ, Divair-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/6200553304840204por
dc.contributor.advisor-co1Calil Junior, Carlito-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/9623336278199725por
dc.contributor.referee1Christ, Divair-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/6200553304840204por
dc.contributor.referee2Calil Junior, Carlito-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/9623336278199725por
dc.contributor.referee3Coelho, Silvia Renata Machado-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/3554106124561773por
dc.contributor.referee4Petrauski, Alfredo-
dc.contributor.referee4Latteshttp://lattes.cnpq.br/3732959853266749por
dc.contributor.referee5Konopatzki, Evandro André-
dc.contributor.referee5Latteshttp://lattes.cnpq.br/2271391188375487por
dc.date.accessioned2021-03-02T13:57:35Z-
dc.date.issued2020-12-11-
dc.identifier.citationFICANHA , Daniele Cristina. Resistência das chapas laterais de silos metálicos utilizando novo modelo de parafuso. 2020. 100 f. Tese( Doutorado em Engenharia Agrícola) - Universidade Estadual do Oeste do Paraná, Cascavel.por
dc.identifier.urihttp://tede.unioeste.br/handle/tede/5243-
dc.description.resumoOs silos metálicos são utilizados para armazenar e preservar a qualidade dos grãos. Para isso, é de suma importância o dimensionamento adequado, a fim de garantir a eficiência e a segurança do equipamento. A possibilidade de implantação de um silo metálico baseia-se principalmente no custo e no peso da matéria prima: o aço. As chapas do costado representam a maior parte da matéria prima utilizada. A viabilização do parafuso alternativo, responsável pelas ligações dos elementos do corpo do silo, aumentam a resistência da chapa lateral. Atentando-se a isto, a possibilidade de meios para aumentar a resistência destas chapas juntamente com a ligação parafusada torna-se atrativa e econômica. Através do parafuso alternativo, capaz de suprir as solicitações de projeto, acarreta-se um novo conceito de dimensionamento estrutural e sistema de montagem das chapas laterais. A análise teórica iniciou-se pela otimização da ligação parafusada com o parafuso alternativo e replicou-se para o parafuso tradicional, analisando os possíveis modelos de acordo com as recomendações da Norma Brasileira 14762. A resistência do conjunto de chapa fina de aço parafusada com o parafuso alternativo foi superior em todas as espessuras compreendidas entre 0,80 e 6,70 mm, quando comparado ao parafuso tradicional. Ligações com costura simples e dupla tornam-se inviáveis para utilização em silos metálicos devido à perda de resistência nas ligações. Tendo em vista os quatro modelos de ruptura, a costura tripla é a ideal. A costura quádrupla eleva a resistência do conjunto, porém ocorrem outras rupturas anteriores ao cisalhamento dos parafusos. Para ensaios experimentais dos conjuntos 0,92 e 3,00 mm, a média da variável aleatória erro de modelo indicou um comportamento experimental seguro e conservador. A confiabilidade dos resultados elevou entre 28 e 34% o dimensionamento teórico, utilizando as normativas vigentes, mesmo desconsiderando os coeficientes de ponderação das ações. Os valores do Coeficiente de redução da área líquida obtidos normativamente também se mantiveram conservadores. As rupturas das amostras 0,92 mm por esmagamento não foram condizentes com o modelo normativo de ruptura da seção líquida na região da ligação. Para as amostras 3,00 mm, confirmou-se o fenômenoteórico com a ruptura da seção líquida na região da ligação. Paraexplicar os resultados experimentais obtidos nessa tese, se propõe expressões matemáticas para os modelos de ruptura da seção líquida na região da ligação e ruptura por esmagamento. O parafuso alternativo se torna uma provável solução nas ligações parafusadas das chapas metálicas utilizadas no costado dos silos.por
dc.description.abstractMetal silos are used to store and preserve grain quality. Thus, proper sizing is of utmost importance, in order to guarantee the efficiency and safety of the equipment. The possibility of implanting a metallic silo is based mainly on the cost and weight of the raw material: steel. The side plates represent most of the raw material used. The possibility of the alternative screw by Ficanha (2016), responsible for the connections of the elements of the silo body, increases the resistance of the side plate. Considering such, the possibility of ways to increase the strength of these plates together with the screw connection becomes attractive and economical. Through the alternative screw, capable of supplying the project requests, a new concept of structural design and assembly system for the side plates is brought about. The theoretical analysis started by optimizing the screw connection with the alternative screw and replicated for the traditional screw, analyzing the possible models according to the recommendations of NBR 14762 (ABNT, 2010). The strength of the thin steel plate set screwed with the alternative screw was higher in all thicknesses between 0.80 and 6.70 mm, when compared to the traditional screw. Connections with single and double seam are not possible for use in metallic silos due to the loss of resistance in the connections. In view of the four rupture models, triple stitching is the ideal one. The quadruple seam increases the strength of the set, but other breaks occur before the shear of the screws. For experimental tests of the 0.92 and 3.00 mm sets, the mean of the model error random variable indicated a safe and conservative experimental behavior. The reliability of the results raised the theoretical dimension between 28 and 34%, using the current regulations, even disregarding the weighting coefficients of the actions. The Ct values obtained normatively also remained conservative. The ruptures of the 0.92 mm samples by crushing were not consistent with the normative model of rupture of the liquid section in the connection region. For the 3.00 mm samples, the theoretical phenomenon was confirmed with the rupture of the liquid section in the connection region.In order to explain the experimental results obtained in this research, mathematical expressions are proposed for the rupture models of the liquid section in the connection region and rupture by crushing. The alternative screw becomes a possible solution in the screw connections of the metal plates used in the side of the silos.eng
dc.description.provenanceSubmitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2021-03-02T13:57:35Z No. of bitstreams: 2 Daniele C. Ficanha.pdf: 4057512 bytes, checksum: e5976be2321f4a7726651f3d1769e233 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceMade available in DSpace on 2021-03-02T13:57:35Z (GMT). No. of bitstreams: 2 Daniele C. Ficanha.pdf: 4057512 bytes, checksum: e5976be2321f4a7726651f3d1769e233 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2020-12-11eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Estadual do Oeste do Paranápor
dc.publisher.departmentCentro de Ciências Exatas e Tecnológicaspor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIOESTEpor
dc.publisher.programPrograma de Pós-Graduação em Engenharia Agrícolapor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectLigação parafusadapor
dc.subjectCoeficiente de redução de área líquidapor
dc.subjectCisalhamento do parafusopor
dc.subjectCostura triplapor
dc.subjectConformação a friopor
dc.subjectBolted connectioneng
dc.subjectNet area reduction coefficienteng
dc.subjectBolted sheareng
dc.subjectCold-formingeng
dc.subjectTriple stitchingeng
dc.subject.cnpqENGENHARIA AGRICOLA::MAQUINAS E IMPLEMENTOS AGRICOLASpor
dc.titleResistência das chapas laterais de silos metálicos utilizando novo modelo de parafusopor
dc.title.alternativeResistance of sidewall sheets of metal silos using new bolt modeleng
dc.typeTesepor
dc.publisher.campusCascavelpor
Appears in Collections:Doutorado em Engenharia Agrícola (CVL)

Files in This Item:
File Description SizeFormat 
Daniele C. Ficanha.pdf3.96 MBAdobe PDFView/Open Preview


This item is licensed under a Creative Commons License Creative Commons