Title: Simulação e avaliação de um sistema de aquecimento solar de água utilizando balanço energético
Other Titles: Simulation and evaluation of a system of solar water heating using energy balance
Autor: Medeiros, Maurício 
Primeiro orientador: Nogueira, Carlos Eduardo Camargo
Resumo: Este trabalho foi desenvolvido na Universidade Estadual do Oeste do Paraná UNIOESTE, campus de Cascavel, e teve por objetivo principal o desenvolvimento de um programa computacional para simular e dimensionar, de forma otimizada, um sistema de aquecimento solar de água. Para determinar os parâmetros de eficiência do sistema, foram instalados três coletores solares de 1,05 m2 cada, da marca Pro Sol, acoplados a um reservatório térmico de 200 litros, contendo resistências elétricas auxiliares de 2000 W. O sistema utilizado funciona por termossifão, e foi instalado em um suporte metálico fixado ao solo, com orientação para o norte, num ângulo de 35º em relação à horizontal. Foram coletados dados horários de radiação solar e temperaturas da água, e avaliados dois cenários. No primeiro cenário, considerou-se a utilização do sistema de aquecimento auxiliar controlado por um termostato, que ligava e desligava as resistências elétricas conforme a temperatura da água no boiler oscilava em torno da temperatura de consumo (40ºC). No segundo cenário, considerou-se o acionamento do sistema de aquecimento auxiliar somente nos horários de consumo de água, quando a temperatura da água no boiler estivesse menor que a temperatura de consumo. Foram calculados os coeficientes de perda de calor no coletor solar e no reservatório térmico, o fator de remoção de calor no coletor solar e a eficiência global do sistema de aquecimento instalado. Esses parâmetros calculados, e os demais dados coletados, foram utilizados no software desenvolvido para simulação e dimensionamento, de maneira a atender satisfatoriamente às necessidades de consumo de água quente, e minimizar os custos totais de instalação e consumo de energia elétrica. Por fim, esses custos do sistema de aquecimento solar foram comparados aos custos de um chuveiro elétrico convencional. Os resultados obtidos foram os seguintes: coeficiente de perda de calor no coletor solar (5,45 Wm-2ºC-1), coeficiente de perda de calor no reservatório térmico (5,34 Wm-2ºC-1), fator de emoção de calor do coletor solar (0,78) e eficiência global do sistema (31%). Os tempos de retorno do capital investido no sistema de aquecimento solar (em comparação a um chuveiro elétrico convencional), para os dois cenários de utilização, foram de, respectivamente, 11,38 anos e 5,73 anos.
Abstract: This work was developed at the State University of West of Paraná UNIOESTE, campus de Cascavel and was aimed at developing a computer program to simulate and scale, optimally, a system of solar water heating. To determine the efficiency parameters of the system were installed three solar collectors of 1.05 m2 each, brand Pro Sol, coupled to a thermal reservoir of 200 liters, containing electrical resistances auxiliary 2000 W. The system works by using thermosyphon, and was installed in a metal bracket fixed to the ground, oriented to the north at an angle of 35 degrees from the horizontal. We collected hourly data of solar radiation and water temperatures, and evaluated two scenarios. In the first scenario, it was considered system utilization auxiliary heating controlled by a thermostat, which linked and hang up the electrical resistances as the temperature of water in boiler oscillated around of temperature of consumption (40 º C). In the second scenario, it was considered the system to power auxiliary heating only in timetables of water consumption, when the water temperature in boiler was lower than the temperature of consumption. Coefficients were calculated heat loss in the solar collector and storage tank, the heat removal factor of solar collector and the overall efficiency of the heating system installed. These calculated parameters and other data collected were used in software developed for simulation and design in order to satisfactorily meet the needs of hot water consumption, and minimize the total installation costs and energy consumption. Finally, these system costs solar heating were compared to costs of an electric shower conventional. The results obtained were as follows: coefficient of heat loss in the solar collector (5,45 Wm-2ºC-1), coefficient of heat loss in the thermal reservoir (5,34 Wm-2ºC-1), removal factor heat of the solar collector (0.78) and overall system efficiency (31%). The times of return on capital invested in the solar heating system (compared to a conventional electric shower), for the two scenarios of use, were, respectively, 11.45 years and 7.81 years.
Keywords: Aquecimento solar de água
Dimensionamento e simulação
Coeficiente de perdas de calor do coletor e reservatório térmico
Solar water heating
sizing and simulation
heat loss coefficient of collector and thermal storage tank
CNPq areas: CNPQ::CIENCIAS EXATAS E DA TERRA
Idioma: por
País: BR
Publisher: Universidade Estadual do Oeste do Parana
Sigla da instituição: UNIOESTE
Departamento: Agroenergia
Program: Programa de Pós-Graduação Stricto Sensu em Energia na Agricultura
Citation: MEDEIROS, Maurício. Simulation and evaluation of a system of solar water heating using energy balance. 2012. 54 f. Dissertação (Mestrado em Agroenergia) - Universidade Estadual do Oeste do Parana, Cascavel, 2012.
Tipo de acesso: Acesso Aberto
Endereço da licença: http://creativecommons.org/licenses/by-nc-nd/4.0/
URI: http://tede.unioeste.br:8080/tede/handle/tede/827
Issue Date: 17-Feb-2012
Appears in Collections:Mestrado em Engenharia de Energia na Agricultura (CVL)

Files in This Item:
File SizeFormat 
Mauricio Medeiros.pdf2.51 MBAdobe PDFView/Open Preview


Items in TEDE are protected by copyright, with all rights reserved, unless otherwise indicated.