Export iten: EndNote BibTex

Please use this identifier to cite or link to this item: https://tede.unioeste.br/handle/tede/4099
Full metadata record
DC FieldValueLanguage
dc.creatorPiva, Luana Caroline-
dc.creator.Latteshttp://lattes.cnpq.br/6493652019800812por
dc.contributor.advisor1Busato , Mauro Carlos Agner-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1189765186576000por
dc.contributor.referee1Busato , Mauro Carlos Agner-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1189765186576000por
dc.contributor.referee2Tondelli , Pedro Marcelo-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/9955183641053025por
dc.contributor.referee3Mendonça , Marcio José-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/7797504639182284por
dc.date.accessioned2019-02-15T19:01:56Z-
dc.date.issued2018-03-26-
dc.identifier.citationPIVA, Luana Caroline. Análise de Prescrições Ortodônticas em Molares com Torques Ideais – Estudo Laboratorial. 2018. 34 f. Dissertação( Mestrado em Odontologia) - Universidade Estadual do Oeste do Paraná, Cascavel, 2018.por
dc.identifier.urihttp://tede.unioeste.br/handle/tede/4099-
dc.description.resumoINTRODUÇÃO: Há uma diversidade de prescrições de aparelhos ortodônticos que o ortodontista dispõe para empregarem sua prática clínica. Também, existe uma escassez de evidências com relação ao efeito da inserção de fios retangulares em tubos ortodônticos de molares sobre o posicionamento final destes dentes quando utilizadas diferentes prescrições. Por isso, esse estudo teve o objetivo de analisar se o torque presente nos tubos dos aparelhos pré-ajustados de diferentes prescrições alteraria a inclinação ideal dos primeiros e segundos molares inferiores e superiores. MÉTODOS: A amostra foi composta por modelos de gesso de 30 pacientes que apresentavam torques ideais. Foram utilizados tubos com slot 0.22x0.028” de quatro prescrições: MBT, Roth, Damon e Edgewise. Os tubos foram colados no modelo de gesso, no centro da coroa clínica de cada dente, face vestibular. Além dessa posição de colagem, foi avaliado, nos modelos inferiores, a posição de um milímetro abaixo do centro da coroa. Mediu-se a a folga entre os fios retangulares de aço (0.019x0.025” e 0.021x0.025”) e os tubos, para verificar se o torque inicial seria mantido, e quantificou-se o torque efetivo. CONCLUSÕES: No fio 0.019x0.025” houve maior número de manutenções do torque ideal, independente da prescrição testada, quando comparado com o fio 0.021x0.025”. A prescrição Roth obteve os resultados mais próximos a zero na avaliação do torque efetivo, indicando uma pequena alteração média do torque.por
dc.description.abstractINTRODUCTION: There is a diversity of prescriptions of orthodontic appliances that the orthodontist has available to use his clinical practice. Also, there is a lack of evidence regarding the effect of insertion of rectangular strands into orthodontic molar tubes on the final positioning of these teeth when different prescriptions are used. Therefore, this study had the objective of analyzing whether the torque present in the tubes of the pre-adjusted devices of different prescriptions would alter the ideal inclination of the first and second lower and upper molars. METHODS: The sample consisted of gypsum models of 30 patients who presented ideal torques. Tubes with 0.22x0.028 "slot of four prescriptions were used: MBT, Roth, Damon and Edgewise. The tubes were glued on the plaster model, in the center of the clinical crown of each tooth, vestibular face. In addition to this gluing position, the position of one millimeter below the center of the crown was evaluated in the lower models. The gap between the steel rectangular wires (0.019x0.025 "and 0.021x0.025") and the tubes was measured to verify if the initial torque was maintained, and the effective torque was quantified. CONCLUSIONS: In the 0.019 wire x0.025 "there were higher number of optimum torque maintenance, regardless of the prescription tested, when compared to 0.021x0.025" wire. The Roth prescription obtained the closest results to zero in the evaluation of the effective torque, indicating a small average torque change.eng
dc.description.provenanceSubmitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-02-15T19:01:56Z No. of bitstreams: 2 Luana_Piva_2018.pdf: 1657544 bytes, checksum: 7b1664bb8a7145180d1b0818ea573db8 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceMade available in DSpace on 2019-02-15T19:01:56Z (GMT). No. of bitstreams: 2 Luana_Piva_2018.pdf: 1657544 bytes, checksum: 7b1664bb8a7145180d1b0818ea573db8 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-26eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Estadual do Oeste do Paranápor
dc.publisher.departmentCentro de Ciências Biológicas e da Saúdepor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNIOESTEpor
dc.publisher.programPrograma de Pós-Graduação em Odontologiapor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectOrtodontiapor
dc.subjectModelos dentáriospor
dc.subjectTorquepor
dc.subjectOrthodonticseng
dc.subjectDental modelseng
dc.subjectTorqueeng
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleAnálise de Prescrições Ortodônticas em Molares com Torques Ideais – Estudo Laboratorialpor
dc.title.alternativeAnalysis of Orthodontic Prescriptions in Molares with Ideal Torques - Laboratory Studyeng
dc.typeDissertaçãopor
dc.publisher.campusCascavelpor
Appears in Collections:Mestrado em Odontologia (CVL)

Files in This Item:
File Description SizeFormat 
Luana_Piva_2018.pdfArquivo completo1.62 MBAdobe PDFView/Open Preview


This item is licensed under a Creative Commons License Creative Commons