DC FieldValueLanguage
dc.creatorVendramin, Aurea Lúcia-
dc.creator.Latteshttp://lattes.cnpq.br/0426402927463618por
dc.contributor.advisor1Souza, Samuel Nelson Melegari de-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0938805013383423por
dc.contributor.referee1Siqueira, Jair Antonio Cruz-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/5644626331586827por
dc.date.accessioned2017-07-10T19:23:56Z-
dc.date.available2008-01-30-
dc.date.issued2007-07-12-
dc.identifier.citationVENDRAMIN, Aurea Lúcia. Method degrees-day for evaluation of the energy performance of a construction unifamiliar in different climatic conditions.. 2007. 75 f. Dissertação (Mestrado em Engenharia) - Universidade Estadual do Oeste do Parana, Cascavel, 2007.por
dc.identifier.urihttp://tede.unioeste.br:8080/tede/handle/tede/2671-
dc.description.resumoA necessidade da aplicação de dados climáticos para avaliação de desempenho energético em edificações unifamiliares tem se tornado cada vez mais importante. Atentando para esse fato, é necessário que essas variáveis sejam trabalhadas de forma a se obter resultados eficazes. Estudos na área são muito recentes no Brasil e existe também uma dificuldade no levantamento dos registros necessários. O presente trabalho utilizou um método de graus dias para uma avaliação do desempenho energético de uma edificação unifamiliar que mostrou que na concepção de um projeto arquitetônico devem ser sempre considerados os materiais empregados na edificação e o tamanho das aberturas. O desempenho energético foi obtido por meio do modelo de graus dias, considerando se a localização da residência unifamiliar nas cidades de Cascavel, Curitiba, Foz do Iguaçu e Londrina. Para isso foram obtidos os dados climáticos dessas localidades e, em um segundo momento, foi obtido o coeficiente total de perda de calor na edificação unifamiliar pré-estabelecida avaliando-se assim as condições de conforto térmico o desempenho energético da edificação. O método de estimativa baseado nas informações de temperatura do ar usado neste estudo pode ser aplicado a outras localidades geográficas. Observou se que graus dias de aquecimento no inverno são de 77,78 para Curitiba e de 0,00 para Foz do Iguaçu na temperatura base de 14°C. E graus dias de resfriamento 30,17 no inverno. A energia consumida em Foz do Iguaçu para aquecer a residência é de 4650.07 kWh anual e o consumo de energia anual para aquecer a residência em Curitiba é de 6277.02 kWh, para trocas de 50% de ITA em vidros duplos.por
dc.description.abstractThe necessity of the application of climatic data for evaluation of energy performance in unifamiliares constructions if has become each more important time. Attempting against for this fact, one becomes necessary that these 0 variable are worked of form if to get resulted efficient. Studies in this area are very recent in Brazil and also exist a difficulty in the survey of the necessary registers. The present work used a method of degrees - days for an evaluation of the energy performance of a unifamiliar construction it showed - that in the conception of a project architectural it always must be taken in consideration of the materials used in the construction and size of the openings. The energy performance was gotten by means of the model of degrees - days, considering - the localization of the unifamiliar residence in, cities of Cascavel, Curitiba, Foz do Iguaçu and Londrina. For this the climatic data of such localities had been gotten and at as a moment, the energy performance of the construction was gotten the total coefficient of loss of heat in the unifamiliar construction daily pay-established evaluating thus the conditions of thermal comfort. The method of estimate based on the information of used temperature of air in this study can be applied to other geographic localities. It observed - that degrees - days of heating in the winter are of 77.78 for Curitiba and 0.00 for Foz do Iguaçu in the temperature base of 14°C. E degrees - days of cooling 30,17 in the winter. The energy consumed in Foz do Iguaçu to heat the residence is of 4650.07 kWh annual and the consumption of annual energy to heat the residence in Curitiba is of 6277.02 kWh, to change of 50% ITA in double glass.eng
dc.description.provenanceMade available in DSpace on 2017-07-10T19:23:56Z (GMT). No. of bitstreams: 1 Aurea Lucia Vendramini.pdf: 426775 bytes, checksum: 564553d1ce5ca6d797acb90f3cf07ad3 (MD5) Previous issue date: 2007-07-12eng
dc.formatapplication/pdfpor
dc.languageporpor
dc.publisherUniversidade Estadual do Oeste do Paranapor
dc.publisher.departmentEngenhariapor
dc.publisher.countryBRpor
dc.publisher.initialsUNIOESTEpor
dc.publisher.programPrograma de Pós-Graduação "Stricto Sensu" em Engenharia Agrícolapor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectMétodo graus-diaspor
dc.subjectcoeficiente total de perda de calorpor
dc.subjectdesempenho energético de uma edificaçãopor
dc.subjectMethod degrees - dayseng
dc.subjecttotal Coefficient of loss of heateng
dc.subjectenergy performance of a constructioneng
dc.subject.cnpqCNPQ::CIENCIAS AGRARIAS::ENGENHARIA AGRICOLApor
dc.titleMétodo graus dia para avaliação do desempenho energético de uma edificação unifamiliar em diferentes condições climáticas.por
dc.title.alternativeMethod degrees-day for evaluation of the energy performance of a construction unifamiliar in different climatic conditions.eng
dc.typeDissertaçãopor